Severity:
Low
Status:
Confirmed
Revision Resolved:
None
Description
Configuring the system to use RS422 or RS485 serial modes on Windows requires using the
SerCx2.sys driver framework. Most existing serial utilities only support the Serial.sys driver
framework, requiring the use of
to use the RS422/485 serial device.
RS232 serial mode uses the Serial.sys driver framework.
Workaround
A UART Sub-Device driver is
, and provides a mapping layer to the
Serial.sys driver framework. This driver does not support setting the DTR/DTS hardware
lines, which may result in compatibility issues with some software packages, including
PuTTy.
Resolution
There are no planned changes to the serial framework.
IP-2: System May Power On After Power Interruption
Overview
Category:
Hardware
Revision(s) Affected:
All release hardware
Severity:
Low
Status:
Confirmed
Revision Resolved:
None
Description
In some cases, after an input power glitch, the system may power on. Brownouts, or other
power events, may result in a previously off system powering on to the BIOS or operating
system.
Workaround
None
Resolution
Investigating