FT-3100 TRANSMITTER PROGRAMMING GUIDE
ONICON Incorporated 727.447.6140
Page 16
onicon.com
This function sets the position of the decimal point when displaying the reverse
flow total.
To move the decimal point, press enter to access the function. Use the up and/
or right arrow keys to change the selection. Press enter to accept the change and
exit the function. Press escape to exit the program mode.
This function sets the measurement units for the on-board temperature sensor.
To change the existing setting, press enter to access the function. Use the right
arrow key to change the selection. Press enter to accept the change and exit the
function. Press escape to exit the program mode.
Enables or disables the mass measurement function. When enabled,
measurement unit lists for flow rates and totals will be in mass units.
To change the existing setting, press enter to access the function and use the up
arrow key to turn the function on or off. Press enter to accept the change and
exit the function. Press escape to exit the program mode.
This function is only enabled when mass units are enabled. The static value
entered here will be used to convert volumetric flow into mass flow.
To enter a new value, press enter to access the function. Use the right arrow key
to move the cursor and the up arrow key to change the coefficient. Press enter to
accept the change and exit the function. Press escape to exit the program mode.
Temperature Unit Type
[Temp. unit = °F]
Partial Reverse Flow Totalizer
Decimal Point Position
[P- D.P. = X]
Mass Units Enable
[Mass units = OFF]
Specific Gravity Coefficient
[Sg = kg/dm
3
X.XXXX]