CS-IO3200 User Manual 

             

 

 

CS-IO3200 

Serial IO Controller 

Manual 

 

 

 

 

Summary of Contents for CS-IO1600

Page 1: ...1 13 CS IO3200 User Manual CS IO3200 Serial IO Controller Manual...

Page 2: ...2 3 PARAMETERS AND WORKING MODE CONFIGURATION 12 3 1 Device and PC Connection Settings 12 3 2 Device Address 12 3 2 1 Introduction 12 3 2 1 Device Communication Address Reading 13 3 2 2 Software Addre...

Page 3: ...nterface cannot be used to establish communication and control After the relay powered on 24 5 2 4 Multiple devices on the 485 bus and close operation failed to send the broadcast address 254 24 5 2 5...

Page 4: ...s and precautions in this manual Please open the package carefully and check whether the device and accessories have been damaged due to transportation when you receive the device Please contact us fo...

Page 5: ...ied by software Support standard Modbus RTU protocol read and write by register address 0 255 Built in address DIP switch Set address codes by software Support input and output linkage such as local l...

Page 6: ...4 Dimension 300 110 60mm 2 Wiring Instructions 2 1 Terminal Definition No Pin Instruction 1 Positive Power Supply 2 GND Negative Power Supply RS232 ground wire 3 Shielded Shielded wire 4 A RS485 comm...

Page 7: ...th DO normally OFF terminal 33 Normally ON The 23th DO normally ON terminal 34 Public The 23th DO public terminal 35 Normally OFF The 23th DO normally OFF terminal 36 Normally ON The 22th DO normally...

Page 8: ...F The12th DO normally OFF terminal 69 Normally ON The 11th DO normally ON terminal 70 Public The 11th DO public terminal 71 Normally OFF The11th DO normally OFF terminal 72 Normally ON The 10th DO nor...

Page 9: ...2nd DO normally ON terminal 97 Public The 2nd DO public terminal 98 Normally OFF The 2nd DO normally OFF terminal 99 Normally ON The 1st DO normally ON terminal 100 Public The 1st DO public terminal 1...

Page 10: ...ble throw and each circuit has three terminals one group is normally ON and the other is normally OFF normally ON contacts are generally used and the terminal identification is subject to the indicati...

Page 11: ...e 2 3 4 AC 380V Load Device Wiring Without Zero Line Please add an AC contactor intermediate relay between this device and the load in the following four cases 1 Load rated voltage 30VDC 2 Load rated...

Page 12: ...that appears after the USB to 485 232 device is inserted is the serial port number 3 2 Device Address 3 2 1 Introduction The Offset Address of this device is 1 by default and the broadcast address is...

Page 13: ...read address on the serial relay debugging software to read the current address of the device only support broadcast read address when there is one device on the bus 3 2 2 Software Address Setting and...

Page 14: ...English Version based on the register table in this article This product supports Modbus RTU format 4 2 Modbus Register Instruction This control card supports communication of various function codes p...

Page 15: ...023 The 23th DO Coil Control 24 00024 The 24th DO Coil Control 25 00025 The 25th DO Coil Control 26 00026 The 26th DO Coil Control 27 00027 The 27th DO Coil Control 28 00028 The 28th DO Coil Control 2...

Page 16: ...ding registers usually store device configuration information In 5 bit code format the first character determines register type and the remaining 4 characters represent address Address 1 starts from 0...

Page 17: ...on FE 05 00 03 FF 00 68 35 Control the 4th DO off FE 05 00 03 00 00 29 C5 Control the 5th DO on FE 05 00 04 FF 00 D9 F4 Control the 5th DO off FE 05 00 04 00 00 98 04 Control the 6th DO on FE 05 00 0...

Page 18: ...5 00 11 00 00 89 C0 Control the 19th DO on FE 05 00 12 FF 00 38 30 Control the 19th DO off FE 05 00 12 00 00 79 C0 Control the 20th DO on FE 05 00 13 FF 00 69 F0 Control the 20th DO off FE 05 00 13 00...

Page 19: ...off FE 05 00 1F 00 00 E8 03 4 4 Command Details 4 4 1 Control DO Control 1 DO take the first DO OFF as an example other channels refer to this Sending code FE 05 00 00 FF 00 98 35 Field Meaning Note...

Page 20: ...he return value is hexadecimal converted to binary data 0 means off 1 means on F4 DE CRC16 CRC16 checksum of the first 6 bytes of data 4 4 3 Flash ON Flash OFF Command Flash OFF sending code FE 10 00...

Page 21: ...0 00 30 00 02 04 00 04 00 0A 02 6A 11th channel flash OFF command FE 10 00 35 00 02 04 00 04 00 0A C2 55 12th channel flash OFF command FE 10 00 3A 00 02 04 00 04 00 0A 82 15 13th channel flash OFF co...

Page 22: ...mand FF FF FF FF All ON command FF FF FF FF All ON command 00 00 00 00 All OFF command 00 00 00 00 All OFF command F6 0B F7 9F CRC16 Check digit Return code FE 0F 00 00 00 20 40 1C Field Meaning Note...

Page 23: ...mersion environments 5 The relay is a component with a certain service life When the theoretical service life is reached please replace it in time to avoid danger 5 2 FAQ 5 2 1 RS485 RS232 communicati...

Page 24: ...different baud rates 5 2 4 Multiple devices on the 485 bus and close operation failed to send the broadcast address 254 If there are multiple devices on the 485 bus the address of each device cannot...

Page 25: ...l property license express or implied or by hijacking or otherwise OneFex assumes no responsibility other than those specified in the terms and conditions of sale of the product And makes no warrantie...