background image

  

 

 

 

       

 

 

 
 
 
 
 
 

 
 
 

 
 

User Manual, 

PCIe x8 GEN 2 Cable Adapter 

OSS-PCIe-HIB25-x8-H (Host) 

OSS-PCIe-HIB25-x8-T (Target) 

 

Summary of Contents for OSS-PCIe-HIB25-x8-H

Page 1: ...User Manual PCIe x8 GEN 2 Cable Adapter OSS PCIe HIB25 x8 H Host OSS PCIe HIB25 x8 T Target...

Page 2: ...ble adapter 3 1 c Specifications 4 1 d Block diagram 5 2 Initial set up 2 a Unpacking instructions 6 2 b Installation and Removal 6 2 c Installing the host cable adapter 6 2 d Removing the host cable...

Page 3: ...ion between a processor and an I O point 1 b Target cable adapter The target cable adapter Part OSS PCIe HIB25 x25 x8 T installs into the target slot of an OSS 2 slot backplane and extends the PCIe bu...

Page 4: ...esigned to meet the following conditions 3 75W typical 3 3 1 3A Operating Environment designed to meet the following conditions Temperature Range 0 to 50 C 32 to 122 F Relative Humidity 10 to 90 non c...

Page 5: ...er Downstream X8 PCI Express Cable Connector Upstream X8 PCI Express Card Edge Connector PCIe Signal Redriver PCIe Signal Redriver LEDs Cable Present Pwr X8 PCIe Rx X8 PCIe Rx CPRSNT 3 3v Clock Clock...

Page 6: ...rotective bag observing proper ESD safety procedures 2 c Installing the Host Cable Adapter 1 Insert the Host Cable Adapter into a PCIe x8 or x16 add in card slot Make sure that the card is well seated...

Page 7: ...d remove the screw before removing the Host Cable Adapter from the card slot 2 e When using with any third party I O device 1 Install the downstream board into the appropriate PCIe slot 2 Connect the...

Page 8: ...PCIe backplane OSS PCIeBP 2010 P 34 to add an additional PCIe slot to any device OSS XMC HIB25 x8 XMC PCIe x8 Gen 2 host cable adapter installs in an XMC connector on a host carrier board and cables t...

Page 9: ...LK SMBus clock JTAG2 TCK 6 SMDAT SMBus data JTAG3 TDI Test Data Input 7 GND Ground JTAG4 TDO Test Data Output 8 3 3V 3 3 V power JTAG5 TMS Test Mode Select 9 JTAG1 TRST Test Reset 3 3V 3 3 V power 10...

Page 10: ...Transmitter differential pair Lane 5 GND Ground 38 PETn5 GND Ground 39 GND Ground PERp5 Receiver differential pair Lane 5 40 GND Ground PERn5 41 PETp6 Transmitter differential pair Lane 6 GND Ground 4...

Page 11: ...rs PCI Express x8 Connector Pin Assignment Row A Row B Row A Row B Row A Row B Pin Signal Name Signal Name Pin Signal Name Signal Name Pin Signal Name Signal Name 1 GND GND 13 GND GND 24 PETn4 PERp4 2...

Page 12: ...EFCLK Cable REFerence CLocK Provides a reference clock from the host system to the remote system SB_RTN Side Band ReTurN return path for single ended signals from remote systems CPRSNT Cable PReSeNT I...