VISIBLE 

SPECTROPHOTOMETER 

V-10 PLUS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User

’s Manual 

 

 

Summary of Contents for V-10 PLUS

Page 1: ...VISIBLE SPECTROPHOTOMETER V 10 PLUS User s Manual...

Page 2: ...ls 2 Main Specifications 3 Description of Appearance and Keys 4 1 Appearance 4 2 Keypad 5 3 Description of Keys 5 Functions 6 Getting Started 6 Important Guidelines 7 General Operating 7 Measuring 8 1...

Page 3: ...II Warranty 19 Equipment Disposal 19...

Page 4: ...om us and authorized contractual partners The device must be connected to a power outlet that has a protective ground connection If the equipment is used in a manner not specified by the manufacturer...

Page 5: ...ded outlet If the local voltage is not stable a voltage regulator is required Be away from direct sunlight 2 Install Spectrophotometer Placement Place the instrument on the stable table carefully Inst...

Page 6: ...325 1000nm Wavelength Accuracy 2nm Wavelength Repeatability 0 8nm Photometric Range 0 3 3A 0 200 T Photometric Accuracy 0 5 T Photometric Repeatability 0 3 T Spectral Bandwidth 4nm Stray Light 0 3 T 3...

Page 7: ...Keys 1 Appearance Front View 1 2 3 4 Back View 5 10 9 8 7 6 11 1 LCD Display 2 Keypad 3 Lid of Sample Room 4 Rod 5 LCD Contrast Adjust 6 Printer port 7 USB port 8 Cover of Fan 9 Power Socket 10 Power...

Page 8: ...5 2 Keypad 3 Description of Keys SET SET Key Set Parameters GOTO GOTO Key Set Wavelength ZERO ZERO Key Blank PRINT PRINT Key Print measuring result...

Page 9: ...owing chart describes the basic operation of the instrument Turn On and Self check Switch on the power Then the instrument begins to self check and 20 minutes warm up Self check includes the following...

Page 10: ...uring solutions and cleaning and disinfectant materials in accordance with the relevant local laboratory regulations General Operating Select Application Main interface press the key SELECT left to en...

Page 11: ...the Standard Curve After got the Standard Curve by Marked press input the file name and press SELECT left to save Load the Standard Curve Quantitative interface press to select Load Curve press to ch...

Page 12: ...LECT left to record W L 500 0nm 0 000A No W L T Abs 1 500 0 100 0 0 000 2 500 0 100 0 0 000 Test Cancel 2 Quantitation Step 1 Start Quantitation Main Interface press key SELECT left to choose Quantita...

Page 13: ...cient K and B Press to input coefficient K press SELECT left same way set B W L 500 0nm W or k W L 500 0 nm O K Cancel W L 500 0nm Coef f i ci ent K 00000 O K Cancel Method 2 Establish Standard Curve...

Page 14: ...ndard samples in the light path as the screen indicates press to input the concentration press SELECT left to confirm to finish all the standard samples W L 500 0nm Num ber 3 O K Cancel W L 500 0nm I...

Page 15: ...es Put the sample to be tested in the light path press SELECT left to measure Then the test result will display in the data sheet Repeat this step to finish measuring all the samples 500 0nm 0 000A No...

Page 16: ...Test M ode D2 Lam p O n W Lam p O n O K Cancel O K Cancel Turn On Off W Lamp Press to choose W Lamp then press SELECT left to enter into Press to choose On or Off press SELECT left to turn on off W L...

Page 17: ...ut Version Press to choose Version press SELECT left to view version information press any key to return Sof t war e V2 4 2 Har dwar e V1 2 Dar k Cur r ent Reset W L Ver si on O K Cancel Troubleshooti...

Page 18: ...he matching of the cuvettes Dark current error Resample dark current Repair and Maintenance 1 Daily Maintain Check the Compartment After measurement the cuvettes with sample solutions should be taken...

Page 19: ...er supply Switch off the power supply and unplug the socket Step 3 Take out the Fuse Seat Take out the fuse seat by the screwdriver Step 4 Replace a new fuse Pick out the spare fuse 3 15A 250V and rep...

Page 20: ...he socket Step 3 Open the cover Unscrew the 4 screws indicated Each side with 2 screws and remove the cover Rod Step 4 Open the cover of the light chamber Unscrew the 2 screws on the light chamber cov...

Page 21: ...move the lamp seat to Left or Right until it focus on the center of the slot Then fix the screws If the facular deviate to Up and Down then loosen the No 2 screws and move the lamp seat Up and Down u...

Page 22: ...ARRANTY OF MERCHANTABILITY Equipment Disposal This equipment is marked with the crossed out wheeled bin symbol to indicate that this equipment must not be disposed of with unsorted waste Instead it s...

Page 23: ......

Page 24: ...Giorgio Bormac S r l Add VIA DELLA MECCANICA 25 41012 CARPI MO ITALY Tel 39 059 653 274 Fax 39 059 653 282...