ELECTRICAL CONNECTION
2.6.1
Electrical wiring and connections
TURN OFF THE POWER SOURCE BEFORE AND DURING THE
CONNECTION WORK TO AVOID SHOCK HAZARD AND
CONTROLLER DAMAGE.
The controller installation must comply with the wiring diagrams provided.
These furnish all information required by a qualified electrician to perform
wiring operations. In addition to all electrical regulations, the following
conditions must be met:
1. All perforations in the chassis for routing electric cables must be made
underneath the device.
2. All perforations for routing electrical cables should be sealed with
mastic to prevent moisture condensation inside the controller.
3. Sufficient lengths of wire should be provided to allow the removal of
all equipment during service operations.
4. Power cables must be made of copper with 600-volt insulation.
5. Sensor and communication cables must be at a minimum # 22AWG,
shielded and twisted copper pair, and insulated with a PVC sheath.
6. Signal and communication cables must not follow an AC power cable
for more than 60 cm (2 ft.) to prevent electrical noise affecting the signal.
7. To unsheathe a wire, remove 10 mm (0.4 inch) of insulation from the
wire end.
8. An AWG #12 protective ground conductor (preferably stranded copper
wire) must be provided and connected at the required location (MALT).
2.6.2 Wiring diagram
For input/output connection details, please refer to the wiring diagrams
shown in Annex D.
Summary of Contents for AgriShift LCL-0.2-120V
Page 2: ......
Page 35: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 33 ANNEX D WIRING DIAGRAM 3 1 1...
Page 36: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 34 NOTES...
Page 37: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 35 NOTES...
Page 38: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 36 NOTES...
Page 39: ......