Smart Tuning
82
ZX2 User’s Manual
INTRODUCTION
MAIN
APPLICATIONS
& SETTING
METHODS
SPECIFI-
CATIONS
INDEX
SETTING
TRANSITION
CHARTS
DETAILED
SETTINGS
FLOW OF
OPERATION
CONTENTS
PREPARATION
FOR
MEASUREMENT
BASIC
SETUP
TROUBLE-
SHOOTING
Height
Double
Sheet
Detection
Positioning
Eccentricity
and Surface
Deflection
Steps
and
Warpage
Thickness
(2) Tuning of multiple stationary workpieces: Multi-smart tuning
(a mix of workpieces having different color and state)
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
—
—
Set reference workpiece 1 in
place.
Press the
button for three
seconds. When
/
is displayed, release
your finger from the button to
start execution of smart tuning.
* /
is
displayed for one to three
seconds after the button is
pressed, and then
/
is displayed.
If "
" flashes on the
sub-display for three
seconds, it indicates that
tuning was not possible.
Change the response time
setting to a larger value, and
try again.
—
—
Swap the workpiece with
reference workpiece 2 and set it
in place.
Press the
button for three
seconds. When
/
is displayed, release
your finger from the button to
start execution of smart tuning.
When there are three or more
reference workpieces, swap
each workpiece and repeat
the procedure.
The optimum conditions are
set for either reference
workpiece 1 or 2 is set.
* /
is
displayed for one to three
seconds after the button is
pressed, and then
/
is displayed.
If you release your finger from
the button
/
, the result of tuning
workpiece 1 will not be reflected.
If "
" flashes on the
sub-display for three
seconds, it indicates that
tuning was not possible.
Change the response time
setting to a larger value, and
try again.
Hold down for
3 seconds
Pressing down
Pressed down
Flashing
Hold down for
3 seconds
Pressing down
Pressed down
Flashing