3
Response time setting
Press the button to set the
display to
to set display of
the detail menu.
Press the
button to apply
the setting.
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Press the button to display
.
Select the
desired value.
Press the button to select the
response time.
Select the response time to
match the size and moving
speed of the sensing object.
to
60 µs, 120 µs, 240 µs, 500 µs,
1 ms, 2 ms, 4 ms, 8 ms, 12 ms,
20 ms, 36 ms, 66 ms, 128 ms,
250 ms, 500 ms
Press the
button to apply
the setting.
* After the response time is
changed, the smart tuning
results are cleared, so be
sure to re-execute tuning.
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Press to display.
Required
Select the response time to match the size
and moving speed of the sensing object.
Press to display
.
Default value: 500 ms
Press to select