Setting Sensing
ZW User's Manual
75
4
Settings for
Func
tion
Setting Exposure Time Control Mode
Set the exposure time control mode and exposure time (maximum) or exposure time (fixed).
Exposure time and measuring cycle
• For the "AUTO" exposure time control mode, the measuring cycle is twice the preset exposure time upper limit. (The
measuring cycle remains the same even if the actual exposure time is the upper limit or less.)
• For the "MANUAL" exposure time control mode, the measuring cycle twice the exposure time is used.
• If the exposure time is 250
s or less, the measuring cycle is set to 500
s.
Explorer pane
: [Bank] | [(Bank Data Name)] (double click)
Edit pane
: [Sensing setting] icon (
)
Sensing settings window : [Measurement area 1] or [Measurement area 2] - [Exposure time]
Item
Setting item
Setting value
Description
Exposure time
Exposure mode
Auto (default value)
Automatically sets the exposure time within the range that
does not exceed the specified upper limit. Usually, select
this setting.
Manual
Select this mode when you want to specify the exposure
time, and set the exposure time (fixed value).
Exposure time
(maximum)
1 to 1,000 (default value) to 5,000
[
s]
Set the upper limit value of the exposure time when
[Automatic] has been selected for the control mode.
Exposure time
(fixed)
1 to 1,000 (default value) to 5,000
[
s]
Set the fixed value of the exposure time when [Fixed] has
been selected for the control mode.
Control edge
1 surface/2 surfaces/3 surfaces/
4 surfaces/Peak (default value)
Select the measurement surface target for light adjustment.
The peak is the surface of all measurement surfaces having
the highest received light amount.
1
Select the exposure mode from [Exposure
mode].
2
Set [Exposure time (maximum)] and [Control
edge].
The exposure time control mode can also be set by the operating keys on the Sensor Controller.
Setting Exposure Time Control Mode p.230
Important
Note
Summary of Contents for ZW-C1*T
Page 70: ...Operating with Sensor Controller 68 ZW User s Manual MEMO ...
Page 116: ...Setting the System 114 ZW User s Manual MEMO ...
Page 134: ...Controll input signal with PC tool 132 ZW User s Manual MEMO ...
Page 209: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 208 8 2 Troubleshooting 210 ...
Page 319: ...Index ZW User s Manual 317 Index 11 ...
Page 321: ......