System data list
ZW User's Manual
313
APPENDICES
10
10-4 System data list
Data
number
Parameter
default value Setting range/output range
Acquisition
Yes/No
Setting
Yes/No
100
RS-232C data length
1
0: 7 bit
1: 8 bit
Yes
Yes
101
RS-232C parity
0
0: None
1: Off
2: Even
Yes
Yes
102
RS-232C stop bit
0
0: 1 bit
1: 2 bit
Yes
Yes
103
RS-232C baud rate
2
0: 9600
1: 19200
2: 38400
3: 57600
4: 115200
Yes
Yes
104
Flow control
0
0: None
1: ON
Yes
Yes
260
Ethernet protocol
1
0: None
1: TCP server
2: TCP client
3: UDP
Yes
Yes
261
IN port number
9601
0 to 65535
Yes
Yes
262
OUT port number
9601
0 to 65535
Yes
Yes
301
Communications delimiter
0
0: CR
1: LF
2: CR+LF
Yes
Yes
400
Serial data output destination
0
0: OFF
1: Ethernet
2: RS-232C
Yes
Yes
401
Serial data output data format
0
0: ASCII
1: BINARY
Yes
Yes
402
Serial data output number of
integer digits
5
1 to 5
Yes
Yes
403
Serial data output number of digits
past decimal point
6
0 to 6
Yes
Yes
405
Serial data output field delimiter
0
0: None
1: Comma
2: Tab
3: Space
4: CR
5: LF
6: CR+LF
7: Semi-colon
Yes
Yes
406
Serial data output record delimiter
0
0: None
1: Comma
2: Tab
3: Space
4: CR
5: LF
6: CR+LF
7: Semi-colon
Yes
Yes
407
Serial data output zero suppress
0
0: None
1: ON
Yes
Yes
500
Analog output destination
0
0: Voltage
1: Current
Yes
Yes
600
Bank mode
0
0: Normal
1: Judgment value
Yes
Yes
Summary of Contents for ZW-C1*T
Page 70: ...Operating with Sensor Controller 68 ZW User s Manual MEMO ...
Page 116: ...Setting the System 114 ZW User s Manual MEMO ...
Page 134: ...Controll input signal with PC tool 132 ZW User s Manual MEMO ...
Page 209: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 208 8 2 Troubleshooting 210 ...
Page 319: ...Index ZW User s Manual 317 Index 11 ...
Page 321: ......