Setting the Clamp Value
Set the clamp value to output when "Clamp" is selected as processing when measurement is not possible.
Explorer pane
: [Bank] | [(Bank Data Name)] (double click)
Edit pane
: [I/O Settings] icon (
)
I/O Setting Screen
: [Analog output]
2
Select the operation during non-
measurement at [Non-Measurement
Setting].
The operations for when measurement is not possible can also be set with key operations on the Sensor Controller.
Setting operation when measurement is not possible p.344
Item
Setting item
Setting value
Description
Analog output
Clamp output
When the analog output destination is set to current
MIN (approx. 3.4mA)/4 to 20mA (1mA increments)/
MAX (default value: approx. 21mA)
When the analog output destination is set to voltage
MIN (approx. -10.8V)/-10 to 10V (1V increments)/
MAX (default value: approx. 10.8V)
Select the current/voltage at clamp
output.
1
Set the operating mode to the FUN mode.
3-3 Switching operation modes p.61
2
Select the output value at [Output value
when clamp].
Note
Summary of Contents for ZW-C1*AT
Page 17: ...ZW User s Manual 1 15 ...
Page 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Page 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Page 120: ...Setting the System 118 ZW User s Manual MEMO ...
Page 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Page 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Page 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Page 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Page 449: ......