![Omron ZW-7000 Series User Manual Download Page 162](http://html1.mh-extra.com/html/omron/zw-7000-series/zw-7000-series_user-manual_742279162.webp)
Setting the Output Conditions
160
ZW-8000/7000/5000
User's Manual
Setting Hold
Set the hold conditions of the measured value.
The hold function holds (retain) any value from the measured values during the specific time (sampling period),
such as the maximum or minimum value.
Setting the Hold Mode
Set the hold mode of the measured value.
Item
Setting item
Setting value
Description
Hold
Hold mode
Peak
Holds the “maximum value” of the sampling period. The current measurement
value is output after Sampling, and then this state is held until the next
sampling ends.
Bottom
Holds the “minimum value” of the sampling period. The current measurement
value is output after Sampling, and then this state is held until the next
sampling ends.
Peak to Peak
Holds the “difference between the maximum value and the minimum value” of
the sampling period. Mainly select this when detecting vibration, for example.
The current measurement value is output after Sampling, and then this state is
held until the next sampling ends.
Auto Peak
Holds the “maximum value” of the measurement result. Output the
measurement value at each updating of the Maximum value.
Auto Bottom
Holds the “minimum value” of the measurement result. Output the
measurement value at each updating of the Minimum value.
Current
measured value
Output
Max.value
Sampling period
Current
measured value
Output
Min.value
Sampling period
Current
measured value
Output
(Max.value -
Min.value)
Max.value
Sampling period
Min.value
Current
measured value
Output
(Max.value)
Current
measured value
Output
(Min.value)
Summary of Contents for ZW-7000 Series
Page 22: ...20 ZW 8000 7000 5000 User s Manual Index 329 Revision History 332 ...
Page 23: ...ZW 8000 7000 5000 User s Manual 1 21 ...
Page 54: ...Basic Operations for Displaying Measurement Results 52 ZW 8000 7000 5000 User s Manual MEMO ...
Page 96: ...Saving a project 94 ZW 8000 7000 5000 User s Manual MEMO ...
Page 192: ...Saving The Settings 190 ZW 8000 7000 5000 User s Manual MEMO ...
Page 280: ...Connecting by No protocol Communications 278 ZW 8000 7000 5000 User s Manual MEMO ...
Page 281: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 280 8 2 Troubleshooting 282 ...
Page 288: ...Troubleshooting 286 ZW 8000 7000 5000 User s Manual MEMO ...
Page 330: ...Firmware Update 328 ZW 8000 7000 5000 User s Manual MEMO ...
Page 333: ...Index ZW 8000 7000 5000 User s Manual 331 9 APPENDICES ...
Page 335: ......