Using the Area Correction Function
Using the Area Correction Function
The detection area of the static electricity sensor changes and the average electric potential
value inside the detection area is displayed according to the distance between the workpiece
and the sensor head. This is why the area correction function is provided so that the area of
the sensing target can be specified and an accurate electric potential can be displayed.
The area sometimes cannot be corrected correctly due to the charged state and the environment around the
sensing object. If this happens, use the sensor with the area correction function set to OFF.
Selection
Details
OFF
(default)
The entire area is measured.
ON
Only a specific area is measured.
Specify the size of the area [SIZE].
Enter the size of the area to be
sensed (mm dia.) as the [SIZE].
Static Electricity Sensor
ZJ-SD Sensor Head
Detection area (W, W') differs
according to distance (d, d') between
workpiece and sensor head.
d (mm)
W dia. (mm)
d' (mm)
W' dia. (mm)
Average electric potential value
of W and W' is calculated.
Static Electricity Sensor
ZJ-SD Sensor Head
d (mm)
Z dia.
(mm)
W dia.
(mm)
Numerical value after correction on
electric potential value in range Z is
displayed.
Electric potential value after distance
correction with detection area (W) is
determined from distance d
measured by displacement sensor.