Starting and Ending Logging
34
ZG2-DSU User’s Manual
Starting and Ending Logging
The following describes the procedure for starting and ending logging.
Starting Logging
1
Switch to the RUN mode.
2
Either input the START signal or
press the
key.
Logging is started.
Ending Logging
1
Either input the STOP signal or
press the
key.
Logging ends, and data is saved to
the Memory Card.
The Data Storage Unit cannot accept the next
logging operation while data is being saved to
the Memory Card.
Whether or not start of logging can be accepted
can be known by the BUSY signal.
Timing charts p.56
Display details during logging can be changed by the
keys.
TEACH
RUN
FUN
Stopping
←→
Available MB
↑ START
N
ot
e
Available MB ←→
Stopping
ޓޓ
↑
START
CH1 TASK1
ޓ
←→
Stopping
ޓޓ
↑
START
CH1 TASK2
ޓ
←→
Stopping
ޓ
↑
START
To display the amount
of remaining space on a
Memory Card
To display the measurement value of a task
to be logged
Important
Summary of Contents for ZG2-DSU
Page 1: ...User s Manual Cat No Z289 E1 01 Smart Sensor Data Storage Unit ZG2 DSU ...
Page 10: ...8 ZG2 DSU User s Manual MEMO ...
Page 14: ...12 ZG2 DSU User s Manual MEMO ...
Page 38: ...Loading Logging Data to an External Device 36 ZG2 DSU User s Manual MEMO ...
Page 42: ...Transferring Bank Data to the Controller 40 ZG2 DSU User s Manual MEMO ...
Page 52: ...Bank Functions 50 ZG2 DSU User s Manual MEMO ...
Page 86: ...Updating the Firmware 84 ZG2 DSU User s Manual MEMO ...
Page 89: ...6 APPENDICES INDEX 87 ZG2 DSU User s Manual MEMO ...