Installation must be in accordance with the following steps and stated specifications and should be carried out by suitably competent personnel. 

Adherence to the  recommended maintenance instructions forms part of the warranty.

WARNING:

 Do not defeat, tamper, remove or bypass this unit. Severe injury to personnel could result.

  Contact open 

  Contact closed

Tension Range

Rope Slack

Rope Pulled

0mm

3.5mm

14.5mm

17.0mm

Contact Arrangement: XER6022, XER6022-SS, XER1022 and XER1032 Models

1NC/2NC/3NC

1NO/2NO

1NC + 1NO

2NC

2NC + 2NO

3NC + 1NO

96

96

222 min - 239 max

32

10

23

7

89

96

86

4 Mounting Holes Clearance 

for M5 Screws

23

54

XER6022

XER6022-SS

Optional E-Stop Button

cable entry

4 Mounting Holes 

Clearance

for M5 Screws

27.50

34

100

86

cable entry

223 min  -  240 max

Optional E-Stop Button

25

60

110

29

10

143

92

XER1022

Left Sided Model: XER1022-011C3L

4 Mounting Holes 

Clearance

327 min  -  361 max

All Dimensions in mm

Optional E-Stop Button

cable entry

for M5 Screws

27.50

100

86

92

143

110

29

60

25

10

XER1032

34

All Dimensions in mm

All Dimensions in mm

40

49

63

Tension Indicator

Indicator shown with steel rope properly adjusted.

XER Series

Safety, 

Technology 

& Innovation

Operating Instructions for XER6022, XER6022-SS, XER1022 & XER1032

Explosion-Proof Classification

The explosion-proof models of safety interlock switches are specifically designed for potentially explosive atmospheres while retaining the features and operating 

characteristics of the conventional models.

A sealed flameproof contact block makes the explosion-proof interlock switches suitable for use in European Zone 1 and Zone 2 environments, which are typical 

of those found in the chemical and petrochemical industries. All switches are classified by the European method as EEx d II C T6. For a full explanation of the 

classification method, see “Hazardous Location Rating Systems for Interlock Switches” in The Safety Library Section of this catalog.

          

WARNING:

  These switches are not suitable for use in atmospheres containing Group I gases, e.g., methane (firedamp).

          These switches DO NOT meet all conditions of the US classification of Class I, Div 1, due to the differences between European and US classification 

          methods.  In the US and Canada, these products can be used in areas classified as Class I, Division 2 in Groups A (acetylene), B (hydrogen), C (ethylene) and D 

          (propane). 