61
Operating Errors and Countermeasures
Section 5-1
5-1-3
Watch Window Errors
5-1-4
Debug Errors
5-1-5
Timing Chart Errors
Error message
Countermeasure
Tags were regis-
tered up to the limit
of 100 tags. Tags
exceeding this limit
were not registered.
You tried to add more than the limit of 100 tags in total on the
Watch Window. Up to 100 tags will be registered but the
remaining tags will not be registered. Add them to a different
tab or delete unwanted tags before trying to add more.
The limit of 100 tags
has already been
registered.
You tried to add more tags when the limit of 100 tags has
already been registered. Add them to a different tab page or
delete unwanted tags before trying to add more.
Error message
Countermeasure
Specify the delay in
increments of 10 ms.
The delay value of the feedback setting has not been specified
in increments of 10 ms. It must be entered in increments of
10 ms.
Specify the time in
increments of 10 ms.
The pulse input ON time or OFF time has not been specified
in increments of 10 ms. It must be entered in increments of 10
ms.
The feedback set-
ting has already
been made for this
input tag. Overwrite
it?
The input tag that you tried to use for feedback setting already
has feedback setting. To overwrite the setting, click the
Yes
Button, otherwise click the
No
Button.
The limit of 200 con-
ditional expressions
has already been
registered.
You tried to add more than the limit of 200 conditional expres-
sions for the feedback setting You cannot register more than
200 conditions. Delete conditions that are no longer required
before adding new ones.
The pulse input
operation is already
being executed. OK
to stop the opera-
tion?
You tried to use the input pulse operation while it is already
being executed. To stop the pulse input operation and apply a
new pulse input, click the
Yes
Button. To continue the previous
pulse input, click the
No
Button.
Error message
Countermeasure
Tags were regis-
tered up to the limit
of 1,000 tags. Tags
exceeding this limit
were not registered.
You tried to add more than the limit of 1,000 tags in total on
the Timing Chart Window. Delete tags that are no longer
required before trying to add more.
You can also use the timing chart import/export function to
switch between multiple timing chart files for debugging
The I/O break condi-
tion registered for the
tag that was deleted
was removed from
the timing chart.
A tag that was registered as an I/O break condition has been
deleted from the timing chart. It will be deleted from the I/O
break condition.
The I/O breakpoint is
disabled. Do you
want to enable it?
An I/O breakpoint is set but is not enabled. To enable the I/O
breakpoint click the
Yes
Button, to leave it disabled click the
No
Button.
The limit of 10 condi-
tional expressions
has already been
registered.
You tried to add a new condition when the number of condi-
tions registered with the I/O breakpoint has already reached
its limit of 10. Only up to 10 conditions can be added. Delete
conditions that are no longer required before trying to add
more.
Summary of Contents for WS02-CFSC1-E
Page 1: ...OPERATION MANUAL Cat No Z910 E1 02 DeviceNet Safety WS02 CFSC1 E NE1A Logic Simulator...
Page 2: ...DeviceNet Safety WS02 CFSC1 E NE1A Logic Simulator Operation Manual Revised June 2007...
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv...
Page 55: ...40 Zooming In and Out of the Logic Window Display Section 3 8...
Page 81: ...66 Shortcut Key List Appendix A...
Page 85: ...70 Revision History...