3 Part Names and Functions
3 - 10
UHF RFID System V780-series Reader/Writer User’s Manual (EtherNet/IP
TM
) (Z402)
If a minor fault is detected, the NORM/ERR indicators will flash red at 0.4-second intervals.
To recover normal operation, initialize the Reader/Writer settings and then restart the Reader/Writer.
However, if an illegal network setting or an incorrect operating mode is detected during operation, the
RUN indicator will flash red and the Reader/Writer will start in Safe Mode.
Illegal Network Setting or Incorrect Operating Mode Detection during Operation
3-1-8
Operation Indicators for System Errors
Minor Faults
The RUN indicator lights green.
The NORM/ERR indicators flash red
at 0.4-s intervals.
NORM/ERR: Red
RUN: Green
NORM/ERR: Red
NORM/ERR: Red
NORM/ERR: Red
The Reader/Writer starts in Safe Mode.
The RUN indicator flashes green
at 0.4-s intervals.
The NORM/ERR indicators flash red
at 0.4-s intervals.
NORM/ERR: Red
RUN: Green
NORM/ERR: Red
NORM/ERR: Red
NORM/ERR: Red