![Omron V680S Series User Manual Download Page 227](http://html.mh-extra.com/html/omron/v680s-series/v680s-series_user-manual_743116227.webp)
Sec
tion 8
Ope
rat
ion In
ter
fa
c
e
Section 8
Web Browser Interface
225
RFID System
User's Manual
(Modbus TCP)
SET MULTI-READER/WRITER OPERATION
If you change any of the multi-Reader/Writer settings, restart the Reader/Writer. The new settings will be enabled after
the Reader/Writer is restarted.
You can register IP addresses for up to seven Slave Reader/Writers on this view. If you set the Multi-Reader/Writer
Mode to anything other than Disable and set the IP address for a Slave Reader/Writer, the Slave Reader/Writer will
become a Master Reader/Writer.
There can be only one Master Reader/Writer in any one group.
Item name
Description
Setting range
Default setting
Multi Reader/Writer mode
Sets the Multi-Reader/Writer Mode.
Disable, Field extension
mode, or High-speed traveling
mode
Disable
Group setting
You can check the IP address of
Reader/Writers registered as Slave
Reader/Writers and the connection
status of all of the Slave Reader/
Writers.
-
-
IP address
You can set or check the IP addresses
of Slave Reader/Writers No. 1 to 7.
-
-
Status
You can check the connection status
of Slave Reader/Writers No. 1 to 7
with the displayed colors.
Not registered: Gray
Connection failed: Red
Connection successful: Green
-
Click this
bu
tton to set
the displayed
v
al
u
es.