57
RFID System
User's Manual
Section 3
V60
0
and
V6
80 Command
Compa
ri
s
on
Section 3
Commands
V600 and V680 Command Comparison
The V680-series Hand-held Reader/Writer can use commands in either the V600 command format or the
V680 command format. By using V600 commands, production lines that previously used a V600-series
Reader/Writer can use the same application with the V680-series Hand-held Reader/Writer. New functionality
can be used by using V680 commands.
The PARAMETER SET (SP) command is used to switch between the two command formats. V680 and V600
commands are handled as shown in the following tables.
Communications Commands
Communications Subcommands
Controller Control Commands
V680 commands
V600 commands
Command name
Command
code
Communications
specification
Data
specifica-
tion
Command name
Command
code
Data
specifica-
tion
READ
RD
ST
A/H
READ
RD
A/H
SA
A/H
AUTO READ
AR
A/H
BT
A/H
BUTTON READ
BR
A/H
BA
A/H
BUTTON AUTO READ
UR
A/H
WRITE
WT
ST
A/H
WRITE
WT
A/H
SA
A/H
AUTO WRITE
AW
A/H
BT
A/H
BUTTON WRITE
BW
A/H
BA
A/H
BUTTON AUTO WRITE
UW
A/H
DATA FILL
DF
ST
A/H
DATA FILL
FL
A/H
SA
A/H
AUTO DATA FILL
AF
A/H
DATA CHECK
MD
ST
C/K
DATA CHECK
MD
C/K
OVERWRITE COUNT CONTROL
MD
ST
S/L
OVERWRITE COUNT CONTROL
MD
S
CALCULATION WRITE
---
---
---
CALCULATION WRITE
CW
A/S
ID CODE READ
ID
ST
H
ID CODE READ
ID
H
READ WITH ERROR CORRECTION
QR
ST
A/H
---
---
---
WRITE WITH ERROR CORRECTION
QW
ST
A/H
---
---
---
V680 commands
V600 commands
Command name
Command
code
Data
specifi-
cation
Command name
Command
code
Data
specifi-
cation
COMMAND PROCESSING TERMINATE
AA
---
COMMAND PROCESSING TERMINATE
AA
---
ABORT (reset)
XZ
---
ABORT (reset)
XZ
---
V680 commands
V600 commands
Command name
Command
code
Command name
Command
code
COMMUNICATIONS CONDITIONS SETTING
TR
COMMUNICATIONS CONDITIONS SETTING
TR
BASIC FUNCTIONS SETTING
FN
BASIC FUNCTIONS SETTING
FN
SET INFORMATION READ
UL
SET INFORMATION READ
UL
PARAMETER SET
SP
PARAMETER SET
SP