46
Section 3
Communica
tions
Dist
anc
e
s
RFID System
User's Manual
Section 3
Communications Specifications
Communications Distances
V680-D1KP52MT
Communications Distance Specifications (Guaranteed)
When embedding the V680-D1KP52MT into a metal surface, use the V680-HS51, V680-HS52 Antenna.
Transmission will not be possible if the V680-HS63 Antenna is used.
• Measurement Conditions
Amplifier
Antenna
RF Tag
Communications distance
V680-HA63A
V680-HS51
V680-D1KP52MT
Read
0.5 to 6.5 mm (Axis offset:
±
2 mm)
Write
0.5 to 6.0 mm (Axis offset:
±
2 mm)
V680-HS51
V680-D1KP52MT
embedded in metal (steel)
Read
0.5 to 3.5 mm (Axis offset:
±
2 mm)
Write
0.5 to 3.0 mm (Axis offset:
±
2 mm)
V680-HS52
V680-D1KP52MT
Read
0 to 9.0 mm (Axis offset:
±
2 mm)
Write
0 to 8.5 mm (Axis offset:
±
2 mm)
V680-HS52
V680-D1KP52MT
embedded in metal (steel)
Read
0 to 4.5 mm (Axis offset:
±
2 mm)
Write
0 to 4.0 mm (Axis offset:
±
2 mm)
V680-HS63
V680-D1KP52MT
Read
0 to 12.0 mm (Axis offset:
±
2 mm)
Write
0 to 9.5 mm (Axis offset:
±
2 mm)
V680-HS52
Metal
V680-HS63
V680-HS52
Non-metallic material
(Exmamples: Resin, plastic, wood, etc.)
Non-metallic material
Metal
V680-HS51
V680-HS51
V680-D1KP52MT
Metal
Non-metallic material
Non-metallic material
Metal
V680-D1KP52MT
Non-metallic material
(Exmamples: Resin, plastic, wood, etc.)
Non-metallic material
(Exmamples: Resin, plastic, wood, etc.)
Communica-
tions
distance
Communica-
tions
distance
Communica-
tions
distance
Communica-
tions
distance
Communica-
tions
distance
V680-D1KP52MT
V680-D1KP52MT
V680-D1KP52MT