POLLING AUTO WRITE (PW)
When the host device sends a POLLING AUTO WRITE command to the Controller, the Controller
immediately returns a response to the host device indicating reception of the command. Then the
Controller waits for the approaching Tag and writes the data when the Tag is in the communications
area.
When the Tag is in the communications area, the host device can use a subcommand to request the
command processing results. The host device can also send a command to another Read/Write Head.
Name
Details
Data designation
Specifies the code format to be used when transmitting the response for the read data.
A: ASCII
H: Hexadecimal code
Antenna designation
Always 1
Start address
Specifies the start address of the area from which data is to be read from the Tag in 4-digit hexa-
decimal.
Setting range: 0000h to 03E7h
Number of write bytes
Specifies the number of data bytes to be written to the Tag in 4-digit hexadecimal.
Setting range: 0000h, or 0001h to 0080h
* When 0000h is specified, the data will be written to the user area from the specified start
address until the Tag's final address.
Name
Details
End code
Indicates the execution result for the command.
Name
Details
Data designation
Specifies either to request the result of or to abort polling auto processing.
Specifies the code format when sending the read data response.
C: Processing result request
H: Aborted
Antenna designation
Always 1
Command
×
×
P
W
×
×
×
×
H
1
×
×
2
1
1
4
4
@
0
2
×
×
2
*
CR
2
3
Data
type
Antenna
designation
Start address
FCS
Controller No.
Terminator
Write data
Command
code
Response
P
W
×
×
7
4
2
2
2
@
×
×
3
*
CR
2
End code
FCS
Terminator
Command code
Controller No.
Subcommand
P
W
×
×
C/E
1
2
1
2
@
×
×
3
*
CR
2
1
Data
type
Antenna
designation
FCS
Controller No.
Terminator
Command
code