Troubleshooting
Error Tables
■
Host CommunicationsErrors
Host communications errors are errors in communications between the CF Reader/Writer and the
Handy Terminal. The indicator will flash red when a host communications error occurs.
Refer to
for corrective actions for the above errors.
■
Tag Communications Errors
Tag errors are errors in communications between the CF Reader/Writer and a Tag. The indicator will
flash red when a “Tag missing” tag error occurs and will light red when any other tag error occurs.
Refer to
for corrective actions for the above errors.
Error code
Name
Description
10
Parity error
A parity error has occurred in characters in the command.
11
Framing error
A framing error has occurred in characters in the command.
12
Overrun error
An overrun error has occurred in characters in the command.
14
Format error
The command format is incorrect.
The character interval exceeded the set time.
18
Frame length error
A command string longer than 300 characters was received.
Error code
Name
Description
70
Communications error
An error occurred during communications with a Tag, and the communications
could not be completed normally.
71
Verification error
The correct data could not be written to the Tag (possible only when verification is
enabled).
72
No-tag error
There is no Tag in the CF Reader/Writer communications area.
7A
Address designation
error
The designated processing address is not suitable, and the execution is impossible.
7D
Write protection error
Data was written to a write-protected page.
7E
Lock error
Write was specified to a locked area.
7F
Tag error
Communications were attempted with a Tag for which communications are not
enabled (e.g., no password setting).