SECTION 4
Commands
Controller Control Commands
Parameter Setting (SP)
This command sets communications conditions by setting the parameters in the CF Reader/Writer.
* The parameter number for the parameter data is the number specified in the lower digit of the process
code. Set the parameter data within the setting range given for the parameter number specified in the
lower digit of the process code.
Example: Setting Character Interval Monitoring Time to 500 ms
Send data:
SP010500
*
[CR]
Receive data: SP0000
*
[CR]
Process code (upper digit) Specifies the process to be performed for the parameter.
“0”: Change
“1”: Read
“9”: Initialize (default setting)
Process code (lower digit)
Specifies the parameter.
“4”: Auto command abort time
“C”: Write verification
Parameter data
(only when changing the
parameter)
Parameter*
Setting range
4
Set two decimal digits 01 to 60 (unit: 1 s). A command error will occur if 00 is set.
Default is 10 s.
C
0: OFF, 1: ON, Default is 1 (Write varification enabled)
2
2
2
㧖
CR
Command
code "SP"
Parameter data
(only when
changing)
Process
code
(Upper) (Lower)
Command
2
2
1
1
2
㧖
CR
Command
code "SP"
Retry
flag
Parameter data
(only when
reading)
Status
flag
End code
Response