19
Installation Environment
Section 3-2
3-2
Installation Environment
Although the ID Controller V600-CM1D has a high reliability and strong envi-
ronmental durability as a control component, take the following into consider-
ation when installing the ID Controller in order to improve the reliability of the
overall system and to make the best use of its functions:
Installation Location
Do not install the ID Controller at the following locations:
• Where the temperature falls below –10
°
C or rises above +55
°
C, or where
the temperature fluctuation is great and condensation is generated.
• Where the relative humidity falls below 35% or exceeds 85%.
• Where it is subject to corrosive gas, flammable gas, dust, salt, and iron
chips.
• Where it is subject to direct vibration or shock.
• Where it is subject to direct sunlight.
• Where it is subject to splashes of water, oil, and chemical substances.
3-3
Wiring
Input and Output lines
The recommended connector:
Plug type
XM2A-1501 (OMRON)
Hood type
XM2S-1511 (OMRON)
PIN No.
Name
I/O
1
COM
Input
2
RESET
Input
3
TRIG
Input
4
IN1
Input
5
IN2
Input
6
TBD
---
7
TBD
---
8
RUN
Output
9
COM1
Output
10
CMPL
Output
11
COM2
Output
12
OUT1
Output
13
COM3
Output
14
OUT2
Output
15
COM4
Output
Summary of Contents for V600 RFID System
Page 1: ...OPERATION MANUAL Cat No Z193 E1 01 Board Type ID Controller V600 RFID System V600 CM1D...
Page 2: ...V600 RFID System V600 CM1D Board Type ID Controller Operation Manual Produced December 2003...
Page 3: ...iv...
Page 7: ...viii...
Page 10: ...xii...
Page 16: ...6 User I O Section 1 4...
Page 24: ...14 Outline Size Section 2 5...
Page 60: ...50 Communication Time Section 4 6...
Page 82: ...72 Index...
Page 84: ...74 Revision History...
Page 87: ...V6001 RFID System V600 CM1D Board Type ID Controller Cat No Z193 E1 01 OPERATION MANUAL...