220
SECTION
8
Se
rial Int
erf
ac
e
(Nor
ma
l)
V530-R160
Operation Manual
SECTION 8
Communication with the Host
@ MC
Function • • • Changes the mode to
MON
(monitor) mode or
RUN
mode.
Set the mode to 0 to specify
MON
mode or 1 to specify
RUN
mode.
Command executed correctly:
Command not executed correctly:
@ MT
Function • • • Reads the most recent read-processing time.
Command executed correctly:
The 5-digit processing time (00000 to 99999 ms) is returned if the command was
executed correctly.
A value of 99999 will be returned if the actual processing time exceeds 99,999 ms.
A value of 00000 will be returned if the processing time could not be read.
Example: A value of 00230 will be returned when the most recent processing time
was 230 ms.
@
M
C
<Mode>
<Footer>
Send
Receive
O
K
<Footer>
<Header>
E
R
<Footer>
<Header>
@
M
T
<Footer>
Send
Receive
<Footer>
<Header>
<Processing time>