138
Error Codes
Section 6-3
Normal QR Reading Contents
Note
1.
Expressed in 3 digits, e.g., 1 is expressed as 001.
2.
Expressed in 4 digits, e.g., 500 is expressed as 0500.
3.
There are 24 digits total for (1) to (12), including QN.
Output example: QN 025500000032005000000
Area
Item
Number
Settings
Image
input
Shutter speed
(1)
0: 1/250 s
1: 1/500 s
2: 1/1,000 s
3: 1/2,000 s
Background cut upper level (See note 1.)
(2)
1 to 255
Background cut lower level (See note 1.)
(3)
0 to 254
Reading
settings
Symbol color
(4)
0: Black
1: White
Right & left reverse
(5)
0: OFF
1: ON
2: Auto
Gray edge value (See note 1.)
(6)
1 to 127
Gray edge value retry
(7)
0: OFF
1: ON
Timeout (See note 2.)
(8)
200 to 2,000 ms
Display
settings
Reading data
(9)
0: OFF
1: ON
Detailed data
(10)
0: OFF
1: ON
Finder patter
(11)
0: OFF
1: ON
Cell recognition position
(12)
0: OFF
1: ON