Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
4-3
Calibration
Calibration Options
This command specifies the operation of the calibration feature. The default configuration
performs calibration on gain and symbol type. The calibration process optimizes the gain
setting for the configured exposure.
Gain
Note:
If you choose to calibrate the reader by sending a
<@CAL>
command, a decode
is also required for the calibration process to be completed successfully.
Disabled
When disabled, gain is fixed and is not part of the calibration process.
Enabled
When enabled, gain is calibrated to provide the best image quality and performance for
the symbol present in the field of view. Calibration requires that a decodable symbol be
placed in the field of view, as feedback from the symbol decoding process is used to select
the best gain setting. If a symbol is not decoded the process will result in a fail condition.
Gain is enabled by default.
Quick Calibrate
Quick Calibrate
uses the automatic gain control (AGC) feature of the image sensor to
adjust the gain value such that the current image falls into a desirable region of the image
sensor’s sensitivity range, ensuring optimal image luminance. The image sensor converges
on the optimal gain value within a few image frames.
Definition:
When enabled, gain is calibrated to provide the best available image
quality and performance.
When disabled, gain is fixed and is not part of the calibration process.
Serial Cmd:
<
K529,
gain
,exposure,focus position,symbol type,WOI framing,WOI margin,
line scan height,processing
>
Default:
Quick Calibrate
Options:
0 = Disabled
1 = Enabled (Decode Required)
2 = Quick Calibrate
Summary of Contents for V430-F-series
Page 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Page 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Page 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Page 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Page 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...