13-10
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Master Database
Master Database
Important:
The
Master Database
is used for all
Matchcode
modes except
Sequential
and
Wild Card
, both of which use
Master Database Index # 1
.
Master Database Overview
Used where more than one master symbol is required, as in a
Multisymbol
setup, for
matching and other
Matchcode
operations.
Allows the user to define up to 10 master symbols as the master symbol database, which
can be entered by keyboard, scanned in, displayed, or deleted by serial or
ESP
commands.
1. Click the
Master Database
tab.
2. Enable
Matchcode Type
.
3. Set the
Master Symbol Database Size
.
4. Select the database index in which the master symbol will be entered.
5. Do one of the following to enter master symbol data:
a. Double-click the index row to type data directly into the index.
b. Click the
Read Symbol into Selected Index
to enter the next decoded symbol.
Click the
Utilities
button and then the
Master Database
tab to display the Master Database view.
Set
Master Symbol
Database Size
here.
Loads the reader’s saved
master symbols into
ESP
.
Double-click a row to enter data into popup text box.
Loads the next symbol decoded
into the selected index.
Saves the
database to
the reader.
Summary of Contents for V430-F-series
Page 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Page 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Page 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Page 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Page 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...