11-4
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Configuration Database Status
Configuration Database Status
Index
Exposure
Note:
The Exposure parameter is read-only when the reader is in
Continuous Read
mode.
Gain
Focal Distance
Usage:
Useful for applications that require several different complex reader configurations
to be applied sequentially. Multiple database indexes allow you to concatenate
configuration profiles, and to perform more complex operations than would
be possible with only one set of configuration parameters.
Definition:
Determines the specific database index that will be used.
Serial Cmd:
<
K255,
index
,exposure,gain,focal distance,pixel binning,row pointer,column pointer,
row depth,column width,symbology,morphology operator,morphology size
>
Options:
1 to 10
Serial Cmd:
<
K255,
index,
exposure
,gain,focal distance,pixel binning,row pointer,column
pointer,row depth,column width,symbology,morphology operator,morphology size
>
Default:
2500
Options:
50 to 100,000
Serial Cmd:
<
K255,
index,exposure,
gain
,focal distance,pixel binning,row pointer,column pointer,
row depth,column width,symbology,morphology operator,morphology size
>
Default:
0
Options:
0 to 100
Definition:
Provides the focal distance adjustment for the camera.
Any value outside this range will be rejected.
If you attempt to set the Focal distance as the out of range value of your
model, the parameter will be left as-is.
Serial Cmd:
<
K255,
index,exposure,gain,
focal distance
,pixel binning,row pointer,column
pointer,row depth,column width,symbology,morphology operator,morphology size
>
Default:
102
Options:
25 to 4,000 (mm)
100 to 4,000 (1/100 inch)
Summary of Contents for V430-F-series
Page 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Page 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Page 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Page 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Page 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...