Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
7-45
I/O Parameters
ISO/IEC 29158 Symbol Quality Output 1
Note:
Output On under Output 1 Parameters must be set to Symbol Quality for this output
to function.
Automatic identification and data capture – Direct Part Mark (DMP) Quality
Supported symbologies:
Minimum Resolution: 6.0 Pixels Per Element
Output on Overall Grade
Overall Grade Threshold
•
DataMatrix ECC200
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, drives
Output
if grade is under
Overall Grade Threshold.
Serial Cmd:
<
K890,
output on overall grade,
overall grade threshold, cell contrast, cell
contrast threshold, cell modulation, cell modulation threshold, fixed pattern
damage, fixed pattern damage threshold, axial non-uniformity, axial non-
uniformity threshold, grid non-uniformity, grid non-uniformity threshold,
unused ECC, unused ECC threshold>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Usage:
Sets the threshold for driving the output.
Definition:
Conforms to ISO/IEC 29158 symbol quality grading (A,B,C,D).
Serial Cmd:
<
K890,
output on overall grade,
overall grade threshold,
cell contrast, cell
contrast threshold, cell modulation, cell modulation threshold, fixed pattern
damage, fixed pattern damage threshold, axial non-uniformity, axial non-
uniformity threshold, grid non-uniformity, grid non-uniformity threshold,
unused ECC, unused ECC threshold>
Default:
Grade B
Options:
0 = Grade D
1 = Grade C
2 = Grade B
3 = Grade A
Summary of Contents for V430-F-series
Page 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Page 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Page 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Page 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Page 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...