Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
7-11
I/O Parameters
Output Indicators
The V430-series has three LED arrays, as follows:
1. A target pattern of blue LEDs for centering the field of view, which is projected from the
front of the reader.
2. An array of green LEDs projected from the front of the reader that can be programmed
to flash in response to user-defined conditions.
3. A row of five status LEDs on the side of the reader.
Green Flash Mode
Disabled
Green flash LEDs are disabled.
Good Read
Green flash LEDs will flash when a good read condition is met or when
Matchcode
is
enabled and a match occurs.
Usage:
Used as a visual verification that a good read has occurred.
Definition:
An array of green LEDs in the front of the reader can be programmed to
flash in response to user-defined conditions.
Serial Cmd:
<
K750,
green flash mode
,target pattern status,green flash duration
>
Default:
Static Presentation
Options:
0 = Disabled
1 = Good Read
2 = Static Presentation
3 = Match
4 = Mismatch
5 = Strobe