6-38
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
MicroPDF417
MicroPDF417
Fixed Symbol Length Status (MicroPDF417)
Fixed Symbol Length (MicroPDF417)
Note: Fixed Symbol Length Status
must be enabled for
Fixed Symbol Length
to take
effect.
Usage:
Used for labelling small items that need large data capacity.
Definition:
A variant of PDF417, a very efficient and compact stacked symbology
that can encode up to 250 alphanumeric characters or 366 numeric
characters per symbol.
Serial Cmd:
<
K485,
status
,[unused],fixed symbol length status,fixed symbol length
>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
Serial Cmd:
<
K485,
status,[unused],
fixed symbol length status
,fixed symbol length
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Usage:
Used to increase data integrity by ensuring that only one symbol length
will be accepted.
Definition:
When enabled, the MicroPDF417 symbol must contain the same number
of characters as the symbol length setting before it can be considered a
good read. The reader will ignore any symbol not having the specified
length.
Serial Cmd:
<
K485,
status,[unused],fixed symbol length status,fixed symbol length
>
Default:
10
Options:
1 to 366
Summary of Contents for V430-F-series
Page 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Page 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Page 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Page 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Page 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...