5-22
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Capture Timing
Capture Timing
Note:
Capture Timing applies only to
Rapid Capture Mode
.
Time Before First Capture
Usage:
In almost any moving line application, a time delay is needed to ensure that
a symbol will be in the reader’s field of view at the beginning of the capture
sequence.
Definition:
Time Before First Capture
in a moving line application is the time between
an external trigger event and the occurrence of the first capture.
Serial Cmd:
<
K242,
time before 1st capture
,time between capture 1 and capture
2,,,,,,,,time between capture 7 and capture 8
>
Default:
0
Options:
0 to 65535 (2.097 seconds, in 32
µS increments)
Start of
Read Cycle
Time Before First Capture
Processing