TM Conveyor Tracking
Software version: TMflow 1.76
33
Camera calibration:
When using the
camera for the first time, users are
suggested to use this function to
perform a 15-photoshoot calibration.
After 15 photoshoots, the image must
remain normal in TMflow without
twisted shapes (use the calibration
plate to check)
Set Workspace:
Align X-axis of
calibration board parallel to the
conveyor direction, while Y-axis (0,n)
is aligned to the bottom edge of the
screen. The benefits are
•
Obtain a precise value from
object position to camera FOV
edge
•
Obtain a more precise value to
avoid repeated photo taking of
objects
Calibrate Workspace: click
to
configure camera parameters before
calibrating the workspace. Then press
“PLAY/PAUSE” on the robot stick to
start visual navigation
Click “Save” upon completion.
Figure 39 Automatic calibration steps
8
Load Workspace
•
After camera calibration is
completed, click Task Designer.
•
Choose the required Workspace
X-axis