![Omron Sysmac NY512-1300 User Manual Download Page 187](http://html.mh-extra.com/html/omron/sysmac-ny512-1300/sysmac-ny512-1300_user-manual_742451187.webp)
7-71
7 Tag Data Link Functions
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
7-
2 S
e
tti
ng
T
ag
Da
ta
Li
n
ks
7
7-2
-17 Ch
angin
g Devices
You can change devices that are registered in a network configuration with the Network Configurator.
Select
Change Device
from the Device Menu to display a list of the possible devices to change to.
Select the desired device. You can change a device only when there is complete or upward compatibil-
ity with the device.
Yes: Can be changed.
No: Cannot be changed.
* Cannot be changed in any of the following cases:
•
The number of I/O connections, number of tags, number of tag sets, or size of one tag set exceeds the per-
missible settings for the device after the change.
•
RPI exceeds the permissible settings or is set in 0.5-ms increments (such as 10.5 ms).
7-2-17 Changing Devices
Device Changes
Model after change
CJ1W-EIP21(NJ)
NJ501-
NJ301-
NJ101
NX701
NY5
2
Model before
change
CIP
Rev
Rev2
Rev3
Rev1
Rev2
Rev2
Rev2
CJ1W-EIP21(NJ) Rev2
---
Yes
*
*
Yes
*
Rev3
Yes
---
*
*
Yes
*
NJ501-
NJ301-
NJ101
Rev1
Yes
Yes
---
Yes
No
No
Rev2
Yes
Yes
Yes
---
Yes
Yes
NX701
Rev2
Yes
Yes
No
*
---
*
NY5
2
Rev2
Yes
Yes
No
*
Yes
---
Summary of Contents for Sysmac NY512-1300