7 Tag Data Link Functions
7-66
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
Additional Information
You can also execute the Reset service of the Identity object for the Controller to clear the tag
data link settings. The procedures to execute the service from the Network Configurator is given
below.
(1) Connect the Network Configurator to the network.
(2) Select
Tool - Setup Parameters
on the main window.
Then the dialog box for the general parameter settings are displayed.
(3) Specify the target device and message to send.
•
Target Node Address: Enter the IP address of the target device.
•
Service:
Select
Reset
.
•
Class:
Enter
01
.
•
Instance:
Enter
01
.
•
Attribute:
Enter
00
.
•
Data:
Enter
02
.
(4) Click the
Send
Button.
You can save device parameters set in the Network Configurator or device parameters uploaded from
the network in a network configuration file.
1
Select
File - Save As
.
The following dialog box is displayed.
Untitled.nvf is displayed as the default file name.
7-2-14 Saving the Network Configuration File