Variable name
Meaning
Function
Data type
Range of
values
Reference
_EIP_IPAdrCfgErr
IP Address Setting
Error
NX-series CPU Units: Indicates the IP
address setting errors for the communi-
cations port 1.
TRUE:
•
There is an illegal IP address setting.
•
A read operation failed.
•
The IP address obtained from the
BOOTP server is inconsistent.
FALSE: Normal
NJ-series CPU Units: Indicates the IP ad-
dress setting errors.
TRUE:
•
There is an illegal IP address setting.
•
A read operation failed.
•
The IP address obtained from the
BOOTP server is inconsistent.
•
The default gateway settings are not
correct.
FALSE: Normal
BOOL
TRUE or
FALSE
_EIP1_IPAdrCfgErr
Port1 IP Address
Setting Error
Indicates the IP address setting errors for
the communications port 1.
TRUE:
•
There is an illegal IP address setting.
•
A read operation failed.
•
The IP address obtained from the
BOOTP server is inconsistent.
FALSE: Normal
Note
You can use this system-de-
fined variable only for NX-ser-
ies CPU Units.
BOOL
TRUE or
FALSE
_EIP2_IPAdrCfgErr
Port2 IP Address
Setting Error
Indicates the IP address setting errors for
the communications port 2.
TRUE:
•
There is an illegal IP address setting.
•
A read operation failed.
•
The IP address obtained from the
BOOTP server is inconsistent.
FALSE: Normal
Note
You can use this system-de-
fined variable only for the
NX701 CPU Units and NX102
CPU Units.
BOOL
TRUE or
FALSE
_EIP_IPAdrDupErr
IP Address Duplica-
tion Error
NX-series CPU Units: Indicates that the
same IP address is assigned to more
than one node for the communications
port 1.
TRUE: Duplication occurred.
FALSE: Other than the above.
NJ-series CPU Units: Indicates that the
same IP address is assigned to more
than one node.
TRUE: Duplication occurred.
FALSE: Other than the above.
BOOL
TRUE or
FALSE
3 System-defined Variables Related to the Built-in EtherNet/IP Port
3-11
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
3-2 System-defined V
ariables
3
Summary of Contents for Sysmac NX1P2-10 1 Series
Page 8: ...Manual Structure 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 34: ...Revision History 32 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 388: ...9 Socket Service 9 34 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 430: ...12 FTP Client 12 14 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 569: ...I Index I 1 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506 I...
Page 576: ...Index I 8 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 577: ......