Variable name
Meaning
Function
Data type
Range of
values
Reference
_EIP2_RegTarget-
Sta[255]
CIP Communica-
tions2 Registered
Target Node Informa-
tion
Gives a list of nodes for which built-in
EtherNet/IP connections are registered
for CIP communications 2.
This variable is valid only when the built-
in EtherNet/IP port is the originator.
Array[x] is TRUE:
The connection to the node with a target
node ID of x is registered.
Array[x] is FALSE:
The connection to the node with a target
node ID of x is not registered.
Note
You can use this system-de-
fined variable only for the
NX701 CPU Units and NX102
CPU Units.
ARRAY
[0..255] OF
BOOL
TRUE or
FALSE
_EIP_EstbTarget-
Sta[255]
Normal Target Node
Information
NX-series CPU Units: Gives a list of no-
des that have normally established built-
in EtherNet/IP connections for CIP com-
munications 1.
Array[x] is TRUE:
The connection to the node with a target
node ID of x was established normally.
Array[x] is FALSE:
The connection to the node with a target
node ID of x was not established, or an
error occurred.
NJ-series CPU Units: Gives a list of no-
des that have normally established built-
in EtherNet/IP connections.
Array[x] is TRUE:
The connection to the node with a target
node ID of x was established normally.
Array[x] is FALSE:
The connection to the node with a target
node ID of x was not established, or an
error occurred.
ARRAY
[0..255] OF
BOOL
TRUE or
FALSE
_EIP1_EstbTarget-
Sta[255]
CIP Communica-
tions1 Normal Target
Node Information
Gives a list of nodes that have normally
established built-in EtherNet/IP connec-
tions for CIP communications 1.
Array[x] is TRUE:
The connection to the node with a target
node ID of x was established normally.
Array[x] is FALSE:
The connection to the node with a target
node ID of x was not established, or an
error occurred.
Note
You can use this system-de-
fined variable only for NX-ser-
ies CPU Units.
ARRAY
[0..255] OF
BOOL
TRUE or
FALSE
3 System-defined Variables Related to the Built-in EtherNet/IP Port
3-25
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
3-2 System-defined V
ariables
3
Summary of Contents for Sysmac NX1P2-10 1 Series
Page 8: ...Manual Structure 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 34: ...Revision History 32 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 388: ...9 Socket Service 9 34 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 430: ...12 FTP Client 12 14 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 569: ...I Index I 1 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506 I...
Page 576: ...Index I 8 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 577: ......