8 - 9
8 Troubleshooting and Maintenance
E3X-ECT EtherCAT Sensor Communication Unit Instraction Manual
8-1 T
ro
u
b
lesho
o
ting
8
8-1-
4 Sysmac Err
o
r S
tatus Codes
A table that describes the error event codes that are displayed on the Sysmac Studio is given below.
Unit version 1.1 or later is required.
The errors (i.e., events) that can occur in the E3X-ECT EtherCAT Slave Unit are given on
the following pages. Event levels are given as following in the tables:
Maj: Major fault level
Prt: Partial fault level
Min: Minor fault level
Obs: Observation
Info: Information
Refer to the
NJ-series Troubleshooting Manual
(Cat. No. W503) for all of the event codes that may
occur in an NJ-series Controller.
8-1-4
Sysmac Error Status Codes
Error List
Event code
Event name
Meaning
Assumed cause
Level
Reference
Maj
Prt
Min
Obs
Info
04C40000 hex
Sensor Com-
munications
Error
An error occurred in
a Sensor connec-
tion.
•
The Sensor is disconnected.
Ö
11
04C50000 hex
Sensor Com-
munications
Has Not
Been Estab-
lished
Communications
has not been estab-
lished with the Sen-
sor.
•
A sensor is not connected.
Ö
11
14A00000 hex
Non-volatile
Memory
Checksum
Error
An error occurred in
the control parame-
ters.
•
Noise
Ö
12
24780000 hex
Number of
Sensors Ver-
ify Error
The number of Sen-
sors that is con-
nected does not
agree with the set-
tings.
•
The set value does not match
the number of Sensors that are
actually connected.
Ö
12
24790000 hex
Number of
Sensors
Over Limit
Too many Sensors
are connected.
•
More than the maximum num-
ber of Sensors are connected.
Ö
13
34F80000 hex
Dummy Sen-
sors Setting
Error
Too many Dummy
Units are set.
•
There are too many Dummy
Units set, so some Sensors are
not assigned logical unit num-
bers.
Ö
13
04A10000 hex
Non-volatile
Memory
Hardware
Error
An error occurred in
non-volatile mem-
ory.
•
Non-volatile memory failure
Ö
14
Summary of Contents for Sysmac E3X-ECT
Page 1: ...E3X ECT EtherCAT Sensor Communication Unit Operation Manual E413 E1 ...
Page 3: ......
Page 4: ...E3X ECT EtherCAT Sensor Communication Units Operation Manual Revised February 2012 ...
Page 5: ......
Page 29: ...1 EtherCAT Network 1 8 E3X ECT EtherCAT Sensor Communication Unit Instration Manual ...
Page 51: ...4 Installation and Wiring 4 12 E3X ECT EtherCAT Sensor Communication Unit Instraction Manual ...
Page 67: ...5 EtherCAT Communications 5 16 E3X ECT EtherCAT Sensor Communication Unit Instraction Manual ...
Page 137: ...A Appendix A 36 E3X ECT EtherCAT Sensor Communication Unit Instraction Manual ...
Page 139: ...Revision 2 E3X ECT EtherCAT Sensor Communication Unit Instraction Manual ...
Page 140: ......