Monitoring
Section 4-5
98
4-5 Monitoring
This section describes the basic operations for monitoring programs and PLC status.
For program debugging operations, refer to section 5.
4-5-1 Monitoring
Start
1 Switch to the online mode as previously described.
2 In the project workspace, select the program to be monitored.
Changing the Operating Mode
To change the PLC operating mode, select a mode as follows.
PROGRAM Mode:
PLC - Operating Mode
-
Program
MONITOR Mode:
PLC - Operating Mode
-
Monitor
RUN Mode:
PLC - Operating Mode
-
Run
The functions that can be used in each operating mode are as follows:
4-5-2
Monitoring SFC Editor
1 Switch to the online mode as previously described.
The monitor screen of the SFC editor is displayed, as shown below. (*1) (*2) (*3)
2 To stop monitoring, select
Monitor
-
Monitoring
from the PLC menu.
*1:
While the PLC is running, the active step element and the action element under execution
are displayed in yellowish green. The display color can be changed by selecting
Tools -
Options
-
Appearance
.
*2:
While in the
MONITOR
or
RUN
operating mode, present values will be updated according
to the PLC’s operation status. (Present value monitor)
*3:
If an action has an S-series AQ (S, SL, SD), its activity status can be monitored, even
while the step itself is in the inactive status.
Operating mode
Name
Program execution
Online editing
PROGRAM
No OK
Display
OK OK
RUN
OK No
Summary of Contents for SYSMAC CX-Programmer 8.1
Page 1: ...Operation Manual SFC Programming SYSMAC WS02 CXPC1 V8 CX Programmer Ver 8 1 Cat No W469 E1 04...
Page 2: ...ii CX Programmer Ver 8 1 WS02 CXPC1 V8 Operation Manual SFC Programming Revised February 2009...
Page 16: ......
Page 56: ...Precautions When Creating SFC Programs Section 1 5 40...
Page 118: ...Monitoring Section 4 5 102...
Page 150: ...Index 134...
Page 152: ...Revision History 136...
Page 153: ......
Page 154: ......