269
Pulse Outputs
Section 5-3
Origin Compensation
After the origin has been determined, the origin compensation can be set to
compensate for a shift in the Proximity Sensor's ON position, motor replace-
ment, or other change.
Once the origin has been detected in an origin search, the number of pulses
specified in the origin compensation is output, the current position is reset to
0, and the pulse output's No-origin Flag is turned OFF.
Setting range: 80000000 to 7FFFFFFF hex (
−
2,147,483,648 to
2,147,483,647) pulses
I/O Settings
Limit Input Signal Type (NC/NO)
Specifies the type of input signal (normally closed or normally open) being
used for the limit inputs.
0: NC
1: NO
Origin Proximity Input Signal Type (NC/NO)
Specifies the type of input signal (normally closed or normally open) being
used for the Origin Proximity Input Signal.
0: NC
1: NO
Origin Input Signal Type (NC/NO)
Specifies the type of input signal (normally closed or normally open) being
used for the Origin Input Signal.
0: NC
1: NO
Positioning Monitor Time
When the operating mode is set to mode 2, this setting specifies how long to
wait (in ms) for the Positioning Completed Signal after the positioning opera-
tion has been completed, i.e., the pulse output has been completed. A Posi-
tioning Timeout Error (error code 0300) will be generated if the motor driver's
Positioning Completed Signal does not come ON within the specified time.
Setting range: 0000 to 270F hex (0 to 9,999 ms)
The actual monitoring time will be the Positioning Monitor Time rounded up to
the nearest 10-ms unit + 10 ms max.
If the Positioning Monitor Time is set to 0, the function will be disabled and the
Unit will continue waiting for the Positioning Completed Signal to come ON. (A
Positioning Timeout Error will not be generated.)
Executing an Origin Search
Execute ORG(889) in the ladder program to perform an origin search with the
specified parameters.
P
C
ORG(889)
P: Port specifier
Pulse output 0: #0000
Pulse output 1: #0001
Pulse output 2: #0002
Pulse output 3: #0003
C: Control data; Origin search and CW/CCW method: #0000
Origin search and pulse + direction method: #0001
Summary of Contents for Sysmac CP1H
Page 2: ......
Page 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised October 2014...
Page 4: ...iv...
Page 10: ...x...
Page 18: ...xviii...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 76: ...42 Function Blocks Section 1 5...
Page 176: ...142 CP series Expansion I O Unit Wiring Section 3 6...
Page 372: ...338 Analog I O XA CPU Units Section 5 5...
Page 578: ...544 Trouble Shooting Section 8 7...
Page 622: ...588 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 668: ...634 Standard Models Appendix A...
Page 744: ...710 Auxiliary Area Allocations by Address Appendix D...
Page 771: ...737 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 772: ...738 Connections to Serial Communications Option Boards Appendix F...
Page 800: ...766 Specifications for External Power Supply Expansion Appendix H...
Page 806: ...772 Index W Work Area 165 work bits 165 work words 165 write protection 379...
Page 808: ...774 Revision History...
Page 809: ......