12-15
12 Pulse Outputs
CP2E CPU Unit Software User’s Manual(W614)
1
2-1 Over
vie
w
12
12
-1-
3
S
p
ecifications
12-1-3 Specifications
Item
Specifications
Output mode
Continuous mode (for speed control) or independent mode (for position con-
trol)
Positioning (independent mode) instruc-
tions
PULS and SPED, PULS and ACC, or PLS2
Speed control (continuous mode)
instructions
SPED or ACC
Origin (origin search and origin return)
instructions
ORG
Interrupt feeding instructions
IFEED
Linear interpolation instructions
ITPL (N
-type CPU Unit only)
Output frequency
1 Hz to 100 kHz (1 Hz units)
S
-type and N14/20 CPU Unit: 2 pulse outputs
N
3
0/40/60 CPU Unit: 4 pulse outputs
Frequency acceleration and decelera-
tion rates
Set in increments of 1 Hz for acceleration/deceleration rates from 1 to 65,5
3
5 Hz
(every 4 ms).
Changing SVs during instruction execu-
tion
The target frequency, acceleration/deceleration rate, and target position can
be changed.
ORG, IFEED and ITPL instructions cannot be changed.
Duty factor
Fixed at 50%
The duty factor is less than 50% only when the output is less than 125 Hz by
linear interpolation.
Pulse output method
Pulse + direction outputs (CW/CCW outputs cannot be used.)
Number of output pulses
Relative coordinates: 0000 0000 to 7FFF FFFF hex(Accelerating or decelerat-
ing in either direction: 2,147,4
83
,647)
Absolute coordinates:
8
000 0000 to 7FFF FFFF hex(-2,147,4
83
,64
8
to
2,147,4
83
,647)
Pulse output PV’s relative/absolute
coordinate specifications
Absolute coordinates are specified automatically when the origin location has
been defined by setting the pulse output PV with the INI instruction or perform-
ing an origin search with the ORG instruction. Relative coordinates are used
when the origin location is undefined.
Relative pulse/absolute pulse specifica-
tions
The pulse type can be specified with an operand in the PULS or PLS2 instruc-
tion.
Only absolute pulse can be specified with linear interpolation (ITPL) instruc-
tion.
Note
The absolute pulse specification can be used when absolute coordi-
nates are specified for the pulse output PV, i.e. the origin location has
been defined.The absolute pulse specification cannot be used when rel-
ative coordinates are specified, i.e. the origin location is undefined. An
instruction error will occur.
Pulse output PV’s storage location
The following Auxiliary Area words contain the pulse output PVs
Pulse output 0: A277 (leftmost 4 digits) and A276 (rightmost 4 digits)
Pulse output 1: A279 (leftmost 4 digits) and A27
8
(rightmost 4 digits)
Pulse output 2: A5
3
(leftmost 4 digits) and A52 (rightmost 4 digits)
Pulse output
3
: A55 (leftmost 4 digits) and A54 (rightmost 4 digits)
The PVs are refreshed during regular I/O refreshing.
Summary of Contents for SYSMAC CP Series
Page 3: ......
Page 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Page 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Page 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Page 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Page 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Page 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Page 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Page 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Page 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Page 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Page 577: ......