52
Basic Operating Procedure
Section 1-9
• Execute the STUP(237) instruction. The Board or Unit Setup Area can be
changed while the PLC power supply is ON. The STUP(237) instruction
can be used, for example, when a communications sequence for a
modem connection is executed in Protocol Macro Mode to switch the
operating mode to Host Link Mode when a certain condition is estab-
lished. This enables monitoring or programming of the CPU Unit to be
carried out from a host computer. See
Appendix O
Changing Port Set-
tings Using STUP(237).
Executing
Communications
The required data and ladder program are created to perform communica-
tions in the serial communications mode that has been set.
Host Link Communications
Sending C-mode and FINS Commands from Host Computers to PLCs
To send C-mode commands or FINS commands, programs must be created
on the host computer to send commands to PLCs and to receive responses
back from the PLCs. Refer to the
CS/CJ-series Communications Commands
Reference Manual
(W342)
for details.
Sending FINS Commands from PLCs to Host Computers
SEND(090), RECV(098), and CMND(490) can be used to execute slave-initi-
ated communications. Also, programming is required at the host computer to
Inner Board Restart Bit and CPU
Bus Unit Restart Bits
Communications Board/Unit Port Settings
Change Bits
Board
A60800
Unit number
Port 1
Port 2
Units
A50100 (Unit No. 0)
Board
A63601
A63602
A50101 (Unit No. 1)
Units
Unit No. 0
A62001
A62002
A50102 (Unit No. 2)
Unit No. 1
A62101
A62102
A50103 (Unit No. 3)
Unit No. 2
A62201
A62202
A50104 (Unit No. 4)
Unit No. 3
A62301
A62302
A50105 (Unit No. 5)
Unit No. 4
A62401
A62402
A50106 (Unit No. 6)
Unit No. 5
A62501
A62502
A50107 (Unit No. 7)
Unit No. 6
A62601
A62602
A50108 (Unit No. 8)
Unit No. 7
A62701
A62702
A50109 (Unit No. 9)
Unit No. 8
A62801
A62802
A50110 (Unit No. A)
Unit No. 9
A62901
A62902
A50111 (Unit No. B)
Unit No. A
A63001
A63002
A50112 (Unit No. C)
Unit No. B
A63101
A63102
A50113 (Unit No. D)
Unit No. C
A63201
A63202
A50114 (Unit No. E)
Unit No. D
A63301
A63302
A50115 (Unit No. F)
Unit No. E
A63401
A63402
Unit No. F
A63501
A63502
Programming to
send commands and
receive responses.
Host computer
Command
Serial Communications Board/Unit
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...