![Omron SYSMAC CJ1W-SCU21-V1 Operation Manual Download Page 73](http://html1.mh-extra.com/html/omron/sysmac-cj1w-scu21-v1/sysmac-cj1w-scu21-v1_operation-manual_743586073.webp)
44
Basic Operating Procedure
Section 1-9
With a Serial Communications Board, the following words are always allo-
cated.
Installing the Board or
Unit
Serial Communications Board (CS Series Only)
1,2,3...
1.
Press in the lever on the Inner Board installation cover, first on the top and
then on the bottom, and remove the cover.
First word in Setup Area allocated in DM Area:
m = 100
×
unit number
(20 words are used beginning from m,
10 words for each port)
First word allocated in the CIO Area:
n = CIO 1500 + 25
×
unit number
(all words are used beginning with n)
Unit No.
Words
Unit No.
Words
Unit No. 0
D30000 to D30099
Unit No. 0
CIO 1500 to CIO 1524
Unit No. 1
D30100 to D30199
Unit No. 1
CIO 1525 to CIO 1549
Unit No. 2
D30200 to D30299
Unit No. 2
CIO 1550 to CIO 1574
Unit No. 3
D30300 to D30399
Unit No. 3
CIO 1575 to CIO 1599
Unit No. 4
D30400 to D30499
Unit No. 4
CIO 1600 to CIO 1624
Unit No. 5
D30500 to D30599
Unit No. 5
CIO 1625 to CIO 1649
Unit No. 6
D30600 to D30699
Unit No. 6
CIO 1650 to CIO 1674
Unit No. 7
D30700 to D30799
Unit No. 7
CIO 1675 to CIO 1699
Unit No. 8
D30800 to D30899
Unit No. 8
CIO 1700 to CIO 1724
Unit No. 9
D30900 to D30999
Unit No. 9
CIO 1725 to CIO 1749
Unit No. A
D31000 to D31099
Unit No. A
CIO 1750 to CIO 1774
Unit No. B
D31100 to D31199
Unit No. B
CIO 1775 to CIO 1799
Unit No. C
D31200 to D31299
Unit No. C
CIO 1800 to CIO 1824
Unit No. D
D31300 to D31399
Unit No. D
CIO 1825 to CIO 1849
Unit No. E
D31400 to D31499
Unit No. E
CIO 1850 to CIO 1874
Unit No. F
D31500 to D31599
Unit No. F
CIO 1875 to CIO 1899
Setup Area in the DM Area:
D32000 to D32767
Words allocated in the CIO Area:
CIO 1900 to CIO 1999
D32000 to D32009
Port 1 Setup Area
CIO 1900
Software switch
D32010 to D32019
Port 2 Setup Area
CIO 1901 to CIO 1904
Board status
D32020 to D32767
Reserved for the system
CIO 1905 to CIO 1914
Port 1 status
CIO 1915 to CIO 1924
Port 2 status
CIO 1925 to CIO 1999
Reserved for the system
Press in the lever on the top.
Press in the lever on the bottom.
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...