491
E5
@
K Digital Controller Write Protocol
Appendix G
Write Input Digital Filter (Sequence No. 062 (Hex 003E))
Writes the input digital filter.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Write Alarm Hysteresis (Sequence No. 063 (Hex 003F))
Writes the alarm 1 hysteresis and alarm 2 hysteresis.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Write Input Shift Value (Sequence No. 064 (Hex 0040))
Writes the input shift upper limit and input shift lower limit.
Send Data Word Allocation (3rd Operand of PMCR(260))
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
0003 (fixed)
+1
Unit No. (2 digits BCD)
00 to 31
+2
Input digital filter (4 digits BCD)
0000 to 9999
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
0004 (fixed)
+1
Unit No. (2 digits BCD)
00 to 31
+2
Alarm 1 hysteresis
(4 digits BCD)
0001 to 9999
+3
Alarm 2 hysteresis
(4 digits BCD)
0001 to 9999
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
0004 (fixed)
+1
Unit No. (2 digits BCD)
00 to 31
+2
Input shift upper limit (4 digits BCD)
0000 to 9999
+3
Input shift lower limit (4 digits BCD)
0000 to 9999
First word of
send data
Number of send data words
+0
+1
+2
(Undefined)
Unit No.
Input digital filter
First word of
send data
Number of send data words
+0
+1
+2
+3
(Undefined)
Unit No.
Alarm 1 hysteresis
Alarm 2 hysteresis
First word of
send data
Number of send data words
+0
+1
+2
+3
(Undefined)
Unit No.
Input shift upper limit
Input shift lower limit
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...