441
Appendix E
Mitsubishi Computer Link Master
(A-compatible 1C Frame, Model 1)
The Mitsubishi Computer Link Master (A-compatible 1C frame, model 1) Protocol is used to send user-speci-
fied or specific (e.g., Device Memory Read/Write) Computer Link commands using the A-compatible 1C frame
model 1 control protocol from a CS/CJ-series PLC (CPU Unit) connected through RS-232C or RS-422A to a
Mitsubishi PLC (Sequencer CPU Module installed in a Computer Link Module). This protocol enables the
OMRON PLC to be used as the host (master) to remotely execute RUN/STOP for or read/write the device
memory of a Mitsubishi A/QnA/Q-series PLC that is connected either serially or on a MELSECNET/Ethernet
network.
Communications Specifications
Serial Communications Unit/Board
CPU Unit
PMCR(260)
Executing standard system Computer Link Master Protocol
Computer Link Unit
RS-232C or RS-422A (Computer Link)
Mitsubishi PLC
OMRON CS/CJ-series PLC
Computer Link
command
Item
Specifications
Protocol
Computer Link, A-compatible 1C frame, model 1
Transmission path connec-
tion
Multi-point
Host (OMRON CS/CJ-series PLC): Mitsubishi Sequencer CPU Module
1:1, 1:n (n = 32 max), m:n (m+n = 32 max)
Note 1: Specifying the PLC number enables access of the specified Sequencer CPU Mod-
ule on the MELSECNET or Ethernet network.
Note 2: Sending data using slave-initiated communications from the Sequence CPU Unit to
the Host (on-demand function) is not supported.
Communications method
RS-232C, RS-422A (4-wire, half-duplex)
Synchronization method
Start-stop synchronization
Transmission code
ASCII
Data length
7, 8 bits
Note: 8-bit units with “0” added to the beginning of the 7-bit code
Stop bits
1, 2 bits
Error detection method
Horizontal parity (none, 1 bit)
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...