141
Host Link Function for Replacing Existing PLCs
Section 4-6
1:1 Host Link
The frame format for a 1:1 Host Link is the same as that for the 1:N Host Link,
except the @, Host Link Unit No., and FCS are omitted.
• Command Format
• Response Format
4-6-2
Host Link-compatible Device Selection
Pre-Ver. 1.2 Units
In earlier models, when the host computer program used by the C-series Host
Link Unit was reused in a CS/CJ-series PLC, data could not be read normally
for some programs due to the differences in Host Link specifications.
Unit Ver. 1.2 or Later
When Serial Communications Units/Boards with Unit Ver. 1.2 or later are
used, however, the Board/Unit’s Host Link specifications can be switched
according to the CPU Unit or other Unit in which the host computer program is
to be reused.
The Host Link specifications change according to the Host Link compatible
device mode that is selected.
• When the following commands for reading I/O memory (RR, RL, RH, RC,
RD, RJ, and RG) are received, the number of data words in each
response frame that is returned to the host is different.
• When the command for reading the status of the CPU Unit (MS) is
received, the response format that is returned to the host according to the
FAL/FALS instruction execution status is different.
* CR
Terminator
Header code
R D
* CR
Header
code
End code
R D 0 0
Terminator
Command
Name
RR
CIO AREA READ
RL
LINK AREA READ
RH
HR AREA READ
RC
PV READ
RD
DM AREA READ
RJ
AR AREA READ
RG
T/C STATUS READ
Command
Name
MS
PROCESSOR STATUS READ
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...