Appendices
A-6
CJ-series EtherNet/IP Units Operation Manual for NJ-series CPU Unit (W495)
Additional Information
•
The device is found only if it is located below the present cursor position in the Hardware List.
•
To search all the devices, select Hardware in the Hardware List before you perform the search
procedure.
To display the properties of the EDS file, use the following procedure.
1
Select the desired hardware (device) from the Hardware List.
2
Select EDS File
−
Property.
The following dialog box is displayed.
The time and date when the EDS file was created is displayed, along with the device informa-
tion.
To manually add an EDS file or if a device is not displayed correctly in the hardware list, use the follow-
ing procedure to recreate the EDS index file. (This applies to Network Configurator version 3.30 or
higher.)
1
Select EDS File
−
Create EDS Index File.
2
Restart the Network Configurator.
A-2-6
Displaying EDS File Properties
EDS File
−
Property
A-2-7
Creating EDS Index Files
EDS File
−
Create EDS Index File
Summary of Contents for SYSMAC CJ1W-EIP21
Page 8: ...Manual Structure 6 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 42: ...Revision History 40 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 68: ...1 Introduction 1 26 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 266: ...9 FTP Server 9 20 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 431: ...Index 1 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495 I Index...
Page 436: ...Index 6 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495 Index...
Page 437: ......