Chapter 2
2-13
CompoWay/F Communications Procedures
1.Test Data
Set between 0 and 23 bytes of user-defined test data.
Set a value for the test data within the ranges shown below according to the communications data
length.
Note Do not set the value H'40. No response will be returned if this value is included.
2.Response Code
Normal Completion
Error Completion
■
Operation Command
The commands supported by the 3G3JE are listed in the following table. Refer to this table for com-
mand codes and related information.
Service Request PDU
Service Response PDU
Communications data length
Test Data
8 bits
ASCII data: H'20 to H'7E or H'A1 to H'FE
7 bits
ASCII data: H'20 to H'7E
Response code
Name
Description
0000
Normal completion
No errors were found.
Response code
Error name
Description
1001
Command too long
The command is too long.
2203
Operation error
CPU or EEPROM error
MRC
3
0
2
2
2
2
0
5
SRC
Command
code
Related
information
MRC
3
0
2
2
4
0
5
SRC
Response code