background image

P A C K A G E   C O N T E N T S

4  

6    

 H-T40

M

-P Manual Rev.A 

3.5. D

URING

 U

SE

• Emergency stop and other safety functions may not be controlled from the

status display touchscreen.

• Do not use too much force or sharp objects when touching the keys, display, 

etc.

3.6. S

ERVICE

 

AND

 M

AINTENANCE

Only qualified personnel should carry out repairs.

• The agreed warranty applies.

• Before carrying out any cleaning or maintenance operations, disconnect the

equipment from the electrical supply.

• Clean the display and surrounding front cover with a soft cloth and mild

detergent.

• Replacing the battery incorrectly may result in explosion. Only use batteries 

recommend by supplier.

3.7. D

ISMANTLING

 

AND

 S

CRAPPING

• The status display touchscreen or parts thereof shall be recycled according

to local regulations.

• The following components contain substances that might be hazardous to

health and the environment: lithium battery, electrolytic capacitor and
display.

 4 P

ACKAGE

 C

ONTENTS

4

The following parts are found in the box:

• (1) Status Display Touchscreen H-T40

M

-P

• (4) Installation fasteners

• (1) Power connector (connected to 24VDC power input)
• (1) Communication cable from HMI status display touchscreen to G9SP

Summary of Contents for Sti H-T40M-P

Page 1: ...H T40M P Status Display Touchscreen Installation and Operating Manual...

Page 2: ...ckage Contents page 6 Section 5 Specifications page 8 Section 6 Mounting Procedure page 10 Section 7 Grounding page 11 Section 8 Power Supply Wiring page 11 Section 9 Dip Switches page 12 Section 10 C...

Page 3: ...ion and the equipment must themselves ensure that each application is in compliance with all relevant requirements standards and legislation in respect to configuration and safety Only parts and acces...

Page 4: ...ual 3 1 GENERAL Only qualified personnel may install or operate the status display touchscreen The status display touchscreen must be installed according to the installation instructions The status di...

Page 5: ...upplier neither guarantees that the status display touchscreen is suitable for a customer s particular application nor assumes responsibility for a customer s product design installation or operation...

Page 6: ...y and surrounding front cover with a soft cloth and mild detergent Replacing the battery incorrectly may result in explosion Only use batteries recommend by supplier 3 7 DISMANTLING AND SCRAPPING The...

Page 7: ...PAC KA GE C ON TEN TS 7 OMRON STI 99885 0010 Rev A Figure 4 1 Status Display Touchscreen H T40M P Figure 4 2 Installation Fasteners Figure 4 3 Power connector...

Page 8: ...me 10 000 hours Touch screen operations 1 000 000 Active area of display W x H 58 5 x 58 5 mm Brightness cd m2 110 Processor 32 bit RISC Status LED PWR COM1 Storage temperature 10 to 60 C Relative ope...

Page 9: ...SP ECIFICA TIONS 9 OMRON STI 99885 0010 Rev A 5 2 DESCRIPTION OF THE PARTS Figure 5 1 H T40M P Mechanical Drawing 5 3 EXTERNAL AND CUT OUT DIMENSIONS Figure 5 2 External and Cut out Dimensions...

Page 10: ...status display touchscreen into the cut out Insert the fixtures to the holes on the unit and fasten the screws into the front of the panel Do not tighten the screws with too much or uneven force or it...

Page 11: ...status display touchscreen Perform the following steps to wire the power connector 1 Unplug the power connector and unscrew the screws 2 Strip approximately 7 8 mm of insulation Insert the wire all t...

Page 12: ...lt Factory Position 10 CONNECTION TO THE G9SP 10 1 Locate the included RS 232 cable with two DB9 connectors 2 Connect the HMI side of the cable to the status display touchscreen serial DB9 COM1 port 3...

Page 13: ...g on the bottom of the main page of the Status Display Touchscreen If it is not verify the G9SP is powered up has a program running and the communication cable is correctly connected No programming in...

Page 14: ...lar zone is in a run or stop mode Using the zone function with the G9SP requires the programming of the optional communication transmission output bits in the G9SP configurator software The status of...

Page 15: ...Optional Communication Transmission Data Zone 4 Table 12 1 G9SP Optional Output Transmission Data Figure 12 3 G9SP Configuration Example 12 2 SAFETY INPUT STATUS This screen page will display the curr...

Page 16: ...tail screen will display any detected errors A zero 0 indicates that there are no errors present i e normal operations If an error code is displayed click on the Code Help button for a description of...

Page 17: ...screen will display any detected errors If all zeroes 0 are displayed no errors are present i e normal operations If an error code is displayed click on the Code Help button for a description of the...

Page 18: ...is initiated If power loss or communication failure were to occur the machine would remain in a safe state Because there is a chance of this a redundant manual reset switch is recommended Figure 12 8...

Page 19: ...rcuit 13 SCREEN PROPERTIES 13 From the Screen Properties screen the contrast and brightness of the screen can be adjusted Press the up or down button and the display will change immediately Press the...

Page 20: ...nt or addition to the above warranty See http www omron247 com or contact your Omron representative for pub lished information 14 Limitation on Liability Etc OMRON COMPANIES SHALL NOT BE LIABLE FOR SP...

Page 21: ...tems Machine Automation Controllers MAC Programmable Controllers PLC Operator interfaces HMI Distributed I O Software Drives Motion Controls Servo AC Drives Motion Controllers Encoders Temperature Pro...

Reviews: